Mandatory Design Requirements and Work Flow Processes


Unless specifically agreed to in writing as an exception, this specification requires certain processes be carried out and adhered to during all phases of the work.

The service provider will employ or subcontract a registered professional engineer licensed to practice in the state or jurisdiction where any and all work is carried out.

The Passive Transmission System is a ‘‘gas tight’’ system. Preserving the condition of the surface inside the transmission line, antenna, and other parts of the system is critical to long-term stability and trouble-free operation. The Tower and Erection Services provider must contribute to preservation of positive gas pressure at all times practical during installation. The following are minimum requirements and the responsibility of the service provider on-site supervisor:
  • The antenna will be under pressure when it arrives on site. The antenna input terminal will include a gas stop. The gas stop must remain in place until the antenna is safely mounted on the tower and the vertical transmission line and tower top elbow complex are ready for connection to the antenna.
  • The transmission line must be assembled from the ground up. The horizontal line will be mounted in a three-point spring hanger suspension arrangement. The vertical line will be mounted with a minimum of two spring hangers attached to mounting brackets on tower members. At the end of each working day or upon work stoppage because of weather, the in-place line will have a cap provided for the purpose of sealing the transmission line. This cap is to be installed anytime work is stopped for more than 2 hours.
  • Upon completion of installation of the transmission line and before connection to the tower top elbow complex, a precision terminating load will be attached to the line. The line will be purged with dry air or nitrogen whereby the termination load is not tightened gas tight so as to permit ‘‘bleeding’’ of dry air equal to three times the capacity of the line. Usually this can be done overnight or within a few hours. The Passive Transmission Systems supplier representative will make measurements on the line.
  • When the tower-top elbow complex has been installed and connected to the vertical line, the precision load will be moved to the antenna side of the complex, the system pressurized again, and measurements made.
  • After the measurements are complete and the antenna is in place, the gas stop will be removed and the final connection of all components made. Depending on the length of time and weather conditions, it may be necessary to purge the system again. Regardless, the system is to be pressurized to one and a half times the recommended operational pressure. The Passive Transmission System supplier representative will make one final set of measurements. If there are no issues, then the service provider will confer with the buyer’s representative as a final step before dismantling rigging and other tools.
The following paragraphs are extracted intact from the Passive Transmission System Specification and provided for reference information and guidance to the Tower and Erection Services Provider:
‘‘Any antenna designed and supplied according to this specification will incorporate a unique mounting interface to the supporting structure. The antenna manufacturer is solely responsible for designing the antenna and mounting interface. The antenna manufacturer will exchange design reference drawings and information with the tower and erection services provider. The antenna manufacturer will coordinate a mutually satisfactory mounting interface meeting all applicable EIA, SAF, and/or other applicable standards commonly used in such work by both parties. Design documents necessary to guarantee physical orientation of the vertical and horizontal radiation patterns referenced in the RFQ for each site will be provided to the buyer prior to release to manufacture of the antenna. Any work commenced, including material release, prior to approval by the buyer is at the risk of the antenna manufacturer. Approval of any drawings or other information in respect to this requirement does not relieve the antenna manufacturer/supplier of the responsibility for final orientation of the antenna on the support structure. The antenna manufacturer is encouraged to design unique mounting interface to ensure final placement is in accordance with each site’s unique radiation requirements. For example, if a particular antenna is either a tower top mount using a pole in a socket or bolted flange mount, it should have only one way in which to interface with the tower top plate or socket.
‘‘Any antenna designed to comply with this specification will incorporate one or more lifting lugs designed to be an inherent part of the structure through a welding or casting process. Drawings, pictures, illustrations, and design details showing clearly how the antenna is to be attached to lifting cable and tag lines will be provided and subjected to design analysis by third-party erection services providers and structural experts who are qualified to render opinions on safety aspects under all conditions including shipping, handling, installation, operation, or removal. Under no conceivable conditions will this requirement be waived.

‘‘Any antenna made up of panels, feed lines, and mounting bracket subassemblies (i.e. not a single mechanical assembly) will follow the same process as outlined in 2 above, except that these conditions will apply at the sub-assembly level, such as a panel and its feed lines and radiators— a power divider/splitter assembly or sub-component as assembled, tested, and shipped from the factory under pressure with gas barriers in place.

‘‘Upon completion of the assembly of an antenna will be fitted with a gas barrier, including pressure indicator and drain cock, and pressurized at its input connection to a level twice the recommended field pressure value. The pressure shall be maintained continously until disassembled in the field for connection to the tower top elbow complex after mounting on the tower. If pressure drops, the leak shall be investigated and fixed prior to further test or installation work.
‘‘Upon completion of assembly and any other tests deemed appropriate and necessary by the manufacturer, the manufacturer shall carry out pattern tests to demonstrate that the finished antenna meets or exceeds the vertical and horizontal patterns invoked in the RFQ. The manufacturer is encouraged to use scale models to reduce cost and test time. If scale models are used, the buyer must review the design process and extent to which they are used and approve or waive any part of the manufacturer’s standard full-size pattern test.

‘‘If the transmission line component of the system is greater than 300 feet in overall length or if the line will carry more than one RF signal, the line will be laid out in a single assembly and pressurized at twice the normal recommended level under operation in the field with dry air or nitrogen gas commonly used in the industry. The completed, pressurized assembly characteristic impedance will be optimized to a VSWR of 1.02:1 across an occupied bandwidth consisting of the television channel and any FM signals รพ/10 Mhz above and below the bandwidth occupied by all the specified signals. The signal source and detection equipment will be described and noted with serial numbers, the name of the person making the measurements, their qualifications to do such work, and the dates the work was undertaken and completed with all interruptions in the daily routine noted. The line shall be terminated in a precision load of the same characteristic impedance as the line. The source and detection equipment and load used shall be part of the manufacturer’s normal test equipment and its calibration traceable to NBS standards commonly used for such purposes.
‘‘All tower top elbow complex units shall be built, optimized, and tested as a single unit. Upon completion of this process and prior to making ready for shipment, the manufacturer will notify the buyer of this fact and provide evidence that the unit has met or exceeded the agreed-upon specifications. The buyer will examine and approve the unit to be made ready to ship.
‘‘Factory RF Pulse and VSWR measurements must be made and recorded. These will be duplicated in the field. VSWR measurements must be made at intervals of .25 Mhz or less.’’

DESIGN CONSIDERATIONS AND CRITERIA

As with any project, content transport network design and construction is not successful without some amount of performance criteria. Content transport networks are different than ordinary voice and data networks. Ordinary voice and data networks don’t typically do content transport well. On the other hand, design and build a network capable of transporting valuable program content, and voice and data can come along for the ride. Below is a list of considerations and criteria that can be used when preparing to undertake a content transport network project. The following list is not to be taken literally, nor is it exhaustive or all-inclusive:

§  Add a note hereAccess, switching, and transport elements
§  Add a note hereAccess and transport facilities can be terrestrial, satellite, or a combination
§  Add a note hereSwitch facilities will be time (TDM), cell (ATM), or packet (IP)
§  Add a note hereService availability is full-time 24/7 or shared
§  Add a note hereAvailability, reliability, robustness, grade, and quality of service
§  Add a note hereCapital and operating cost
§  Add a note hereGeographical or physical coverage includes local (LAN), metropolitan (MAN), regional, national, and global turf (WAN)
§  Add a note hereLANs may have single or multiple segments covering a room, floor, building or group of buildings in a campus arrangement
§  Add a note hereA MAN typically involves third party telco or ISP service and uses standard telephone facilities, such as E1/T1, E3/DS3
§  Add a note hereWAN extends LAN and MAN to wider geographic areas not covered by local telephone companies and ISPs
Add a note hereContent transport networks can be built or bought, but practical realization is a combination of buying equipment and the rights to use facilities and services.

Live, streaming content requires continuous, uninterrupted connections with an equal amount of bandwidth. That’s the theory; however, in practice it’s always prudent to leave just a tad of headroom. So how much is a tad? Practicality drives such in the form of how the service provider divides up the bandwidth and sells it. For example, a 10 Mbs ATM or IP network facility likely won’t be precisely 10 Mbs. These animals usually break out in increments of octal numbers. So somewhere around 10 Mbs will be something like 10240000. If that is your choice of network transport channel, then the compression system output bitrate should be set at some number less than the channel rate. This parameter is also a victim of practical circumstances as well because these devices commonly have to deal with octal numbers. So a tad in practice happens to be the difference between the highest speed the encoder can be set at, and the channel rate. (See Appendix II for an example of calculating payloads and matching channel rates.)
Add a note hereNon–real-time content can be transported using continuous, uninterrupted connections, but it can also be carried on discontinuous bandwidth connections, usually at lower cost and improved utilization of the facilities. Be aware that realization of lower cost is dependent on obtaining use of facilities and services at unit prices based on time used and type of bandwidth occupied for each session or transmission just like the old fashioned long distance telephone call.
Add a note hereStandard network performance and characteristics must be understood before they can be applied to content transport networks. The next few paragraphs provide an introduction to time division multiplexing (TDM), ATM, and IP network technology.
Add a note hereTDM technology characteristics and performance are the standard cell and packet based network performance should be measured against. If a standard for TDM is required, then use wire, fiber, or another passive conductor of known performance. The characteristics of interest include available channel bandwidth, bit error rate, and jitter. However, in cell and packet networks, bit errors cause cell and packet loss or impairment, as can jitter.
Add a note hereATM transport technology offers 5 classes of service. Constant bit rate (CBR), variable bit rate—real-time (VBR-rt), variable bitrate— non–real-time (VBR-nrt), unspecified bit rate, and available bit rate. While it may change in the future, ATM CBR is currently the only ATM class of service capable of transporting high-quality, high bit rate content in real time.
Add a note herePacket-switched networks are inherently chaotic unless specifically configured to deal with continuous signal, or mixed-signal traffic and class-of-service. Packet networks are either Ethernet or IP. (Several packet or packet-like techniques exist; however, they only support content transport as a file transfer, not real time.)
Add a note hereIn general there are two types of IP technology and methodology: Ethernet and Internet. The IEEE 802.1 standard defines Ethernet. Internet or more precisely, IP is defined in RFC 791. Ethernet transport of IP is defined in RFC894.
Add a note hereEthernet architecture is built around shared media in the form of common set of cabling where the information is carried in packets, and the device such as a workstation or server listens or monitors the buss before attempting to establish a connection or session. The way the process works, end-to-end, has the sender and all the receivers constantly listening or monitoring the buss. A session is kicked off after a sender sends an initial transmission to all stations using a unique address. If the initial transmission has a valid destination address, that is an actual receiver connected to and listening to the buss, it responds with an acknowledgement. After the sender receives the acknowledgement, then and only then do the two computers establish a connection and carry on with the session using their unique address information.
Add a note hereIP networks, the Internet in particular, behave in similar fashion as Ethernet.
Add a note hereAll these types of transport work well for moving files, including hypertext markup language—coded pages, fixed images, and other static objects. Uncongested networks may even support low volume continuous signals such as produced by voice or telephone service over IP, and even ‘‘work okay’’ with higher bandwidth continuous signals. Make no mistake about it though, unstructured networks cannot be relied on for transport of continuous signal, high bit rate, valuable content such as audio, video, closed captioning, control, or other signals associated with, or embedded in, program content.
Add a note hereReliable, predictable, safe, and secure content transport requires network connections with sufficient bandwidth, grade, and quality of service (GOS, QOS). Even non–time-sensitive or non–real-time transport—so-called FTP—should be planned and implemented with care because of the size of the files and the time required to move them have significant economic implications.
Add a note hereObtaining sufficient bandwidth, GOS, and QOS is a matter of specifying and configuring LAN, MAN, and WAN network resources.
Add a note hereSufficient, continuous bandwidth means the network must exhibit bandwidth equal to or greater than the bandwidth of all traffic, not just program content if the network is required to accommodate email, web surfing, network management, and perhaps voice. Insufficient network bandwidth results in denial of service or, at best, delayed service. Program content payload bandwidth is roughly equivalent to the sum of compressed audio, video, and other signals multiplexed into a program stream or included in a file object stored on the system. When more than one real-time stream is present on the interface simultaneously, the aggregate of all the program streams cannot exceed the bandwidth available on the interface points of the sending and receiving systems and the network connecting the systems. In other words, the bandwidth of the sending and receiving systems must equal or, preferably, exceed the aggregate of all traffic.
Add a note hereGOS means the network connecting all workstations and servers must be available to all users within the design limits agreed to or promised to its users. For example, telephone network services use statistical probability based metrics to define and measure GOS level, inside and outside the network. A P.01 GOS means the network is designed and performs, or doesn’t perform, within the limits of probability that the network will enable the user to complete the call in 99 of 100 attempts. This model can be applied to workstations, servers, and a LAN, MAN, WAN or combination of all and will perform satisfactorily 99 of 100 times when someone wants to transfer a file, or set up and use a connection to deliver streaming content originating on a server platform and terminating in one or more peer platforms at other locations or interfaces served by the network.
Add a note hereQOS means that the quality of the connection in terms of bandwidth, bit-error rate (BER), jitter, packet loss or any other parameter the payload may be sensitive to, is of sufficient level to support program content transport between and amongst the service points. The basic model for this category of network is classic TDM facilities found in ANSI/ITU standards-based networks. The acid test of performance is measurement and comparison to TDM private line facilities such as E1/T1, E3/DS3, and OC3/STM1. A good question of network equipment, facilities, and service suppliers is: Can you emulate T1, or DS3, etc.? The right answer is not ‘‘Yes.’’ The right answer is, ‘‘You can expect jitter, packet loss and bit error rate performance of x, y, and z. This compares to TDM emulation performance of x, y, and z.’’ Then you can decide if the differences fit into your required performance and compare one supplier to another.
Add a note hereIngest, play out, and file transfer of program content as promised in many product and service descriptions require network connections with sufficient bandwidth, GOS, and QOS. Even non–time-sensitive or non–real-time transport—so-called FTP—should be planned and implemented with care because the size of the files and the time required to move them have significant economic implications.
Add a note hereStandard, so-called out-of-the-box or plug-and-play default LAN configuration included with recent generation Microsoft Operating systems (OS; W2000 Workstation & Server; WXP) enable non– real-time or FTP program content transport. Connect Ethernet to a network interface card (NIC) with access to the Internet, install the OS, run the Internet wizard, and voila! Instant success. No further fuss or effort and file transfer across the Internet from one host to another is possible.
Add a note hereThese operating systems also permit configuration of an NIC to enable QOS as specified in IEEE 802.1p, a method whereby packets carrying continuous content can be marked and differentiated so LAN segments can isolate and protect the content from the effects of congestion and chaos mentioned above. Ethernet packets mapped to IP enable QOS marking to be passed to the IP network. If the network has differentiated services capability, real-time content transport across the network is possible. Older operating systems (NT 4; 95/98) do not include 802.1p/QOS capability.
Add a note hereTwo types of connections are possible, and both may be required by the application. These include Unicast, or point-to-point, and multicast, or point-to-multipoint. These types of connections enable single or multiple deliveries of files or streams, sometimes referred to as objects.
Add a note hereThe basic elements of a content transport network include customer premises equipment (CPE), access facilities at each location, and backbone transport in between. The equipment must be selected and configured to support the level and type of traffic. For example, if the traffic is program content only, that’s one set of circumstances. If the network is to carry voice, data, and provide Internet access, that’s another. If the network is to carry multiple types of traffic, the equipment and facilities will have to be structured to accommodate it. Figure 1 shows a general reference architecture capable of supporting voice, data, and content transport.



Figure 1: Premises Equipment Architecture
Add a note here
Add a note hereThere are several characteristics of the architecture that should be pointed out and commented on. First, note the presence of a network clock reference and a separate station synchronizing reference. Neither has anything to do with the other and that’s the point. The network clock reference is to make sure the network is stable and jitter-free because it must carry the embedded program clock reference along with the content. After all, if the network isn’t capable of carrying the program clock reference to a satisfactory degree of accuracy, then the content will suffer impairment.
Add a note hereAlthough there appears to be a single-thread router and network interface, this is purely symbolic, and emblematic of the same level of redundancy as implied in the private branch exchange, LAN router, and Moving Picture Experts Group (MPEG) Codec. Resolving reliability, robustness and network performance concerns may require redundant equipment and facilities, with emphasis on content value and specific traffic levels. The terms and symbols are generic and intentionally chosen to cover several alternatives without stating them implicitly. For example, any new facility design should take a serious look at voice-over IP telephone service. New installations or even replacement/upgrade installations, may find economic advantage in fully integrated voice and data on LAN wiring. And although, not likely, it may be more appropriate to use ATM switching and transport for real-time program content than IP or TDM transport.
Add a note hereOn the network side, there are similar issues and concerns; however, they must be addressed with carriers or service providers instead of manufacturers of equipment. As a design exercise, network access, transport, and switching should logically follow the food chain whereby the network facilities support movement of content within and between the creation, distribution, and delivery sections of the model. For example, moving raw, unedited content from a location to an editing facility, or moving finished program material from the post-production facility to a network operations center. And of course there’s the end link, which requires the content to be moved from anywhere else to cable head end, DBS uplink, Internet access facility, or digital television transmitter input.
Figure 2 is a network topology diagram showing the details of how the basic elements fit into an overall architecture serving users located at separate sites, or operating centers.



Figure 2: Reference Architecture
Add a note here
Add a note hereAll the various elements must be specified and priced out in detail. CPE is a capital investment. Access and backbone transport is an operating expense and can be provided by third parties, such as Internet service providers (ISPs), ILECs, CLECs, or inter-exchange carriers. Obviously, it is advantageous to deal with a single source for these services. Decisions on the end-to-end solution should only be made after following a due diligence process. Building the simplest of networks is not easy. Scaling start-up or small networks to larger networks becomes geometrically more complex. Churn and change after a network is built, debugged, and operational can be risky and should not be attempted without careful planning and deliberate, task oriented, sequential steps.
Add a note hereSimilar to the end-to-end service model, the reference architecture simply lays out the functional components and shows how they relate. The NID or premises equipment interfaces and interoperates with the network to set up and tear down connections, monitor performance, and process alarms. The desired content transport network leverages one or more routing, switching and transport capabilities, depending on requirements and configuration of the access facilities. In situations where multiple types of traffic are converged onto a common access facility, the access facility must be channelized and mapped to the particular transport. For example, voice grade dialup or switched service would have channel capacity sufficient to accommodate peak voice demand on the public switched telephone network (PSTN) or integrated services digital (ISDN) network. However, if the design called for voice-over IP, some amount of bandwidth would be required to accommodate a similar level of voice traffic.
Add a note hereCPE is a router configured to connect to peer routers at the other locations. The router must be sized and have features selected to perform the functions required by the servers. These functions vary and depend on the encoded bit rate or payload of the content and level of traffic.
Add a note hereAnother factor for careful consideration is distance between peer devices at other locations. If the distance is short, such as a nearby building, Ethernet could be an option. But outside adjacent buildings within a campus environment it’s likely construction and capital cost will quickly add up to make third-party service providers with IP transport capability attractive.
Add a note hereAccess facilities provide basic connectivity between the CPE and the MAN or WAN. Likely alternatives include E3/DS3 or OC3/STM1. Choosing an appropriately sized access facility is a matter of making a conservative estimate of initial traffic level, then monitoring the traffic and adjusting capacity to levels consistent with acceptable utilization and growth plans.
Add a note hereBackbone transport varies based on requirements and usually comes with significant and critical services attached. For example, the access facility is a dumb, point-to-point, TDM unchannelized facility. But routed networks include services such as routing and configuration protocols, IP address provision, service configuration and management that depend on processing functions resident in edge and core routers. It naturally follows that the owner of the core backbone equipment should provide these services.